← Return to COA Analysis Center
Melanotan II 10mg
Lot #1 · Tested May 3, 2026
✓ Third-Party Lab Verified
Melanotan II (CAS 121062-08-6) is a cyclic synthetic analog of α-melanocyte-stimulating hormone studied in preclinical research for its interactions with melanocortin receptors and applications in pigmentation and receptor pharmacology research. This certificate documents the analytical results for ITide Labs’ Melanotan II 10mg, Lot #1, tested by Freedom Diagnostics.
Sample Summary
| Sample Information | |
|---|---|
| Product | Melanotan II 10mg |
| Volume / Fill | 10mg |
| Lot | Lot #1 |
| Accession # | 2605010293 |
| Date Received | May 1, 2026 |
| Date Reported | May 3, 2026 |
| Appearance | White Lyophilized Powder |
| Identity | Confirmed by LC-MS |
| Net Content | 10.34 mg |
| Testing Laboratory | Freedom Diagnostics, USA |
Purity Analysis
The analytical results below were produced by Freedom Diagnostics using validated HPLC-UV and LC-MS methods. Purity reflects the percentage of the target compound relative to all detected substances in the sample.
What This Test Measures
HPLC-UV Purity: Measures the percentage of the sample that is the stated compound. ITide Labs’ threshold is ≥98% — all products on this page meet or exceed this standard. A result above 99% reflects exceptional analytical-grade purity.
LC-MS Identity: Confirms that the compound detected matches the molecular profile of Melanotan II 10mg by mass-to-charge ratio. This test verifies correct molecular identity, not biological activity or safety.
Full Certificate of Analysis
The certificate below is the unmodified document issued by Freedom Diagnostics for Accession #2605010293.
Test History
1 independent lab test on file for this product.
Frequently Asked Questions
-
High-Performance Liquid Chromatography with UV detection (HPLC-UV) is the industry-standard method for measuring compound purity. A dissolved sample is passed through a chromatographic column under pressure; components separate based on chemical properties and a UV detector measures each peak. Peak areas are quantified to determine the percentage of the target compound relative to all detected substances.
-
Liquid Chromatography-Mass Spectrometry (LC-MS) confirms molecular identity. After chromatographic separation, the sample enters a mass spectrometer measuring the precise molecular weight and fragmentation pattern. This is compared against the known molecular signature of the target compound. “Identity: Confirmed” means the observed mass spectrum matches the expected molecular profile — confirming the compound is what it claims to be.
-
No. “Identity Confirmed” is a molecular identification result only — it means the detected compound matches the molecular profile of the stated compound by mass spectrometry. It does not constitute a safety assessment, clinical evaluation, or approval for use in humans. All ITide Labs products are supplied exclusively for laboratory research purposes. This certificate is a scientific characterization document, not a safety certification of any kind.
-
Yes. The lot number on your vial corresponds directly to this certificate. Each vial in this batch was filled from the same tested lot. If your vial shows a different lot number, contact us and we will provide the corresponding certificate for that specific batch.
-
Net content is the actual measured mass of the target compound in the vial, in milligrams. This differs from the nominal fill weight because it accounts for residual moisture, counterions, and other substances present in lyophilized preparations. A net content slightly above or below the labeled amount is normal and reflects the true bioactive compound mass as measured by the laboratory.
-
ITide Labs partners exclusively with Freedom Diagnostics, an independent, accredited analytical laboratory in the United States. We selected them for their validated LC-MS and HPLC-UV capabilities, established accreditation, and consistent reporting standards. Freedom Diagnostics has no financial relationship with our product sourcing — all testing is conducted at arm’s length to ensure objective, unbiased results.
-
Each vial is labeled with a lot number (e.g., Lot #1). This corresponds to the batch shown at the top of this certificate. The accession number assigned by Freedom Diagnostics can be used to cross-reference with the laboratory’s records. If you received a vial from a different lot, contact our team and we will provide the corresponding certificate of analysis.
Research Use Only
All products sold by ITide Labs LLC are intended strictly for laboratory research use by qualified researchers. These products are not approved by the FDA or any regulatory agency for human consumption, therapeutic use, or veterinary application. This certificate of analysis is a scientific characterization document and does not imply suitability for any use beyond laboratory research. By accessing or using this product, the purchaser acknowledges they are a qualified researcher and accepts full responsibility for compliance with all applicable laws and regulations in their jurisdiction.